At one fictional Canadian plant, total emissions rise from 100 to 120 tonnes of CO₂e, while emissions per accepted panel fall from 5.0 to 4.0 kilograms. The two figures move in opposite directions because the panel count rises faster than the emissions total. Keep both numbers in the comparison. Each answers a different question.
First check what each number covers. A dashboard can count inspection events where you need distinct finished panels. An emissions summary can include a second plant while the output record still covers the first. In either situation, decide which comparison is still supported before carrying any percentage into the next version.
Define the count and the total
Use supplied emissions totals. For each period, ask the person who owns the record to identify its dates, site, covered activities and emissions sources. Keep the source version beside the figure. Separately ask production for the output count, the rule for including a panel and the dates and work it covers. Look at those descriptions together before dividing.
The GHG Protocol’s target guidance distinguishes an emissions total from emissions relative to a measure such as output. For an intensity target, it recommends also reporting absolute emissions from the covered sources. GHG Protocol Corporate Standard
This worksheet compares two completed periods. It begins with totals already supplied for the stated work. In the example, the output count includes each distinct finished accepted panel once. Plant 1 is the stipulated boundary. The two periods are consecutive and each lasts 12 months. All figures and records below are fictional.
Calculate both changes on the matched records
Measure the total in metric tonnes of CO₂e and the rate in kilograms of CO₂e per accepted panel. Multiply the tonnes by 1,000 before calculating the rate.
Period A. 100 tonnes × 1,000 = 100,000 kg CO₂e. Divide by 20,000 accepted panels for 5.0 kg CO₂e per panel.
Period B. 120 tonnes × 1,000 = 120,000 kg CO₂e. Divide by 30,000 accepted panels for 4.0 kg CO₂e per panel.
For each percentage, subtract that measure’s A value from its B value, divide by its own A value and multiply by 100. Using the starting value from a different row changes the question.
Total emissions. (120 − 100) ÷ 100 × 100 = 20% higher.
Accepted output. (30,000 − 20,000) ÷ 20,000 × 100 = 50% higher.
Emissions per accepted panel. (4.0 − 5.0) ÷ 5.0 × 100 = 20% lower.
The total tells you how much the supplied emissions number changed. The rate relates that total to the output from the same covered work. Here the number of panels increases by half, while the tonnes increase by a fifth. Dividing the larger total by a panel count that grew faster gives a smaller figure per panel. That arithmetic leaves open what changed in the plant and how much any particular action contributed.
Test a different count of output
Start again from A. The emissions records still cover the same Plant 1 work and periods. This time, the B dashboard’s 30,000 entries are inspection checks, including 6,000 repeat checks. The dashboard alone cannot give the count used in A, which is distinct finished accepted panels.
Hold B’s comparable output count and the changes in output and emissions per panel. The matched emissions totals still support 20% higher total emissions. That part of the comparison can stand while production checks the count.
Ask the production lead for a B record that connects each accepted panel to its identifier and final status, with the same period and finished-output rule as A. Simply subtracting the repeat checks cannot tell you whether every remaining entry is a distinct finished accepted panel. In this example, the production lead verifies that the corrected count is 24,000.
Now divide 120,000 kg by 24,000 panels. The result is 5.0 kg CO₂e per panel, equal to A. The verified output count is up 20% using (24,000 − 20,000) ÷ 20,000. Total emissions are still up 20%, so the verified intensity change is 0%. Keep the dashboard figure in the record with its original label so the reason for the different result stays visible.
Test a different emissions boundary
Return to the original A and B output records. Both still count accepted Plant 1 panels, and the B count is a verified 30,000. This time, the 120-tonne B summary includes Plants 1 and 2. The A emissions record covers Plant 1 only.
Hold the change in total emissions and the change per panel. The 120 tonnes are still a supplied figure for both plants, and the 30,000 panels still support a 50% rise in verified Plant 1 output. Pairing those B figures would put two plants’ emissions over one plant’s output. Comparing 120 to A’s 100 would also mix coverage.
Ask the person who supplied the B total for a separate Plant 1 record covering the same work, sources and length of time. If no such record is available, leave the two emissions comparisons open. In this example, the record owner supplies a matching Plant 1 B subtotal of 96 tonnes. Attach that separately from the two-plant figure and record which version you used.
Matched B rate. 96 tonnes × 1,000 = 96,000 kg. Divide by 30,000 panels for 3.2 kg CO₂e per panel.
Matched total change. (96 − 100) ÷ 100 × 100 = 4% lower.
Matched rate change. (3.2 − 5.0) ÷ 5.0 × 100 = 36% lower.
In this version, both emissions figures fall. The change in interpretation comes from having the right Plant 1 subtotal for the comparison. The raw two-plant figure can still answer a different question about the work it covers.
Copy the comparison worksheet
Give the completed record a version date. Retain the original inputs if you receive a replacement record.
Question. Total emissions, emissions per unit or both ___ / covered site and work ___ / person responsible for the comparison ___.
Emissions for each period. Start and end ___ / site, activities and sources covered ___ / total in metric tonnes ___ / converted kilograms ___ / source file and version ___.
Output for each period. Dates, site and work ___ / product and counting rule ___ / unique accepted units ___ / corrections and evidence ___ / production record and version ___.
Result by measure. Matched basis confirmed ___ / A and B totals ___ / A and B per-unit rates ___ / A value used for each percentage ___ / verified changes or hold by measure ___.
Next action. Missing record or scope explanation ___ / owner of the answer ___ / check date ___ / version to use once verified ___.
A period with zero comparable output has no per-unit figure. An unconfirmed compatible count also leaves the rate on hold. If a comparable measure starts at zero, you can still give the difference where both values are known. A percentage change from that starting point is undefined.
Before passing along the comparison, read each result with its units, period and coverage. Where a number is on hold, name the exact record that would let you finish it. If a buyer is asking a separate question about the condition of an industrial property, our guide to matching environmental reports to an Ontario property sale shows how to check whether the report covers the site and issue under review.
This guide is for general information and education. The fictional examples illustrate how to compare supplied figures. Confirm your own records and their coverage before relying on a comparison.
Subscribe to Deal Flow Canada for practical owner guides and Canadian deal updates.


